Questions and answers of the customers
There are no questions yet. Be the first to ask a question about this product.
₹ 14,986.00 GST included
Switched Mode Power Supply. Modular Construction Auto Resettable Fuse Surge Protection for all Input and outputs. Programmable AC loss delay/Trouble Remainder/Alarm Verification Battery polarity reversible protection Surface Mount Technology Over All current consumption is low. Fully complies with UL -864 and NFPA-72. Rugged CRCA sheet with powder coated finish Operates on 110 220v 50 /60 Hz, AC Mains power supply. 16×2 Dot Matrix LCD Display. 4/8 Class B Style B or Style C initiating device circuit (IDC). All zones accept smoke detectors and any normally open contact device. Any Zone can be configured as Alarm or supervisory Zone. 2ClassBNotificationApplianceCircuits(NAC). NAC shall be programmed as silenceable or Non Silenceable. Supervisory Zone shall be Latching or Resettable. Standby (battery) backup 24v DC power supply with built in charger Error free Fire / Fault status in unambiguous colored LED indication. System ON indication. Main, Standby status audible and visual indication. Battery Low visual warning with audible tone. FormC relays for fire, fault and supervisory. Resettable / Steady 24V D.C. Output. RS 485 Communication facility (Optional). Lamp Test facility. All field wiring circuits are Power limited except 110 220v AC and Battery. All field wiring circuits are supervised. Walk Test facility. Zone Isolation facility with loop voltage cut off. Earth fault annunciation facility at 0 ohms. AC Low voltage cutoff. Programmable AC loss delay / Alarm verification / Trouble reminder.
For 365 days
Only Reputed Brands
Multiple payment options
The microprocessor based UL listed 8 Zone conventional fire alarm control panel, the system has 16 X 2 LCDcharacter, 8 zones detection circuit,3 common potential free contacts &2 common NAC sounder output, inbuilt Rs-485 for repeater connectivity, wall/ceiling mounted, Switch mode power supply- SMPS & Battery polarity & Deep discharge protection. RE-2558 fire alarm control panel is designed with unique protocol to be used for small & medium establishments, Schools, hospitals, hotels, banks, residential / commercial building, and small scale industries. The system is user friendly with includes all standard to ensure ease for use and high reliability. Switched Mode Power Supply. Modular Construction Auto Resettable Fuse Surge Protection for all Input and outputs. Programmable AC loss delay/Trouble Remainder/Alarm Verification Battery polarity reversible protection Surface Mount Technology Over All current consumption is low. Fully complies with UL -864 and NFPA-72. Rugged CRCA sheet with powder coated finish Operates on 110 220v 50 /60 Hz, AC Mains power supply. 16×2 Dot Matrix LCD Display. 4/8 Class B Style B or Style C initiating device circuit (IDC). All zones accept smoke detectors and any normally open contact device. Any Zone can be configured as Alarm or supervisory Zone. 2ClassBNotificationApplianceCircuits(NAC). NAC shall be programmed as silenceable or Non Silenceable. Supervisory Zone shall be Latching or Resettable. Standby (battery) backup 24v DC power supply with built in charger Error free Fire / Fault status in unambiguous colored LED indication. System ON indication. Main, Standby status audible and visual indication. Battery Low visual warning with audible tone. FormC relays for fire, fault and supervisory. Resettable / Steady 24V D.C. Output. RS 485 Communication facility (Optional). Lamp Test facility. All field wiring circuits are Power limited except 110 220v AC and Battery. All field wiring circuits are supervised. Walk Test facility. Zone Isolation facility with loop voltage cut off. Earth fault annunciation facility at 0 ohms. AC Low voltage cutoff. Programmable AC loss delay / Alarm verification / Trouble reminder.
X
There are no questions yet. Be the first to ask a question about this product.
No products in the cart.
Reviews
There are no reviews yet.