Showing 1–20 of 81 results

Show sidebar

Ravel RE-102R 2 Zone Conventional Fire Alarm Control Panel

 6,195.00
Ravel RE-102R 2 Zone Conventional Fire Alarm Control Panel, which uses conventional input devices. The Outputs include Notification Appliance Circuits
Add to cart

Agni 4 Fire Alarm Panel

 3,426.72
Agni 4 Fire Alarm Panel of Microprocessor based fire alarm panels provides a reliable and cost effective solutions to fire detection, for small installation which is 2 zone.
Add to cart

ASES Thirty two Zone microprocessor based Fire alarm Panel Model No.PR–32Z

 38,291.00
Advance Micro controller basedFire Alarm Panel 10 to 48 zone Expandable 16x2 character LCD Display Mains, A. C. Fail, fuse, Charging,Rev. Batt. Indication Zone wise fire, open, short LED indications Zone wise fire, open, short testing facility Zone healthy indications Zone isolations facility through switch Extra Potential free contact for fire & fault Trickle & fast charging facility Reset ,alarm cancel, Lamp test, controls etc Compatible with any make conventional smoke & heat detector 485 Communication for Repeater & Mimic Panels Common fire, fault annunciation facility.
Add to cart

ASES Twenty Four Zone microprocessor based Fire alarm Panel Model No.PR–24Z

 31,045.80
Advance Micro controller based Fire Alarm Panel. 10 to 48 zone Expandable. 16x2 character LCD Display. Mains, A.C Fail, fuse, Charging, Rev. Batt. Indication. Zone wise fire, open, short LED indications. Zone wise fire, open, short testing facility. Zone healthy indications. Zone isolations facility through switch. Extra Potential free contact for fire & fault. Trickle & fast charging facility. Reset ,alarm cancel, Lamp test, controls etc. Compatible with any make conventional smoke & heat detector.
Add to cart

ASES Twenty Zone microprocessor based Fire alarm Panel Model No.PR–20Z

 27,494.00
Advance Micro controller based Fire Alarm Panel. 10 to 48 zone Expandable. 16x2 character LCD Display. Mains, A.C Fail, fuse, Charging, Rev. Batt. Indication. Zone wise fire, open, short LED indications. Zone wise fire, open, short testing facility. Zone healthy indications. Zone isolations facility through switch. Extra Potential free contact for fire & fault. Trickle & fast charging facility. Reset ,alarm cancel, Lamp test, controls etc. Compatible with any make conventional smoke & heat detector.
Add to cart

ASES Sixteen Zone microprocessor based Fire alarm Panel Model No.PR–16Z

 22,715.00
Menu Based Operations. Expandable upto 72 Zones. 128x64 Graphical Display. 4x4 Matrix Keypad. Inbuilt Real Time Clock. Data Logging upto 500 Events. All Zones and Hooter can be enable/disable through Keypad. Auto Calibration feature. Low and High Voltage alert on Display. Extra potential free contact for Fire & Fault. Trickle & Fast Charging Facility. Compatible with any make Smoke & Heat Detector.
Add to cart

ASES Twelve Zone microprocessor based Fire alarm Panel Model No.PR–12Z

 16,484.60
Advance Micro controller based Fire Alarm Panel. 10 to 48 zone Expandable. 16x2 character LCD Display. Mains, A.C Fail, fuse, Charging, Rev. Batt. Indication. Zone wise fire, open, short LED indications. Zone wise fire, open, short testing facility. Zone healthy indications. Zone isolations facility through switch. Extra Potential free contact for fire & fault. Trickle & fast charging facility. Reset ,alarm cancel, Lamp test, controls etc. Compatible with any make conventional smoke & heat detector.
Add to cart

ASES Ten Zone microprocessor based Fire alarm Panel Model No.PR–10Z

 15,399.00
Advance Micro controller based Fire Alarm Panel. 10 to 48 zone Expandable. 16x2 character LCD Display. Mains, A.C Fail, fuse, Charging, Rev. Batt. Indication. Zone wise fire, open, short LED indications. Zone wise fire, open, short testing facility. Zone healthy indications. Zone isolations facility through switch. Extra Potential free contact for fire & fault. Trickle & fast charging facility. Reset ,alarm cancel, Lamp test, controls etc. Compatible with any make conventional smoke & heat detector.
Add to cart

ASES Eight Zone microprocessor based Conventional Fire Alarm Panel, LCD and LED both Model No. IR–8Z

 10,325.00
Menu Based Operations. Expandable upto 72 Zones. 128x64 Graphical Display. 4x4 Matrix Keypad. Inbuilt Real Time Clock. Data Logging upto 500 Events. All Zones and Hooter can be enable/disable through Keypad. Auto Calibration feature. Low and High Voltage alert on Display. Extra potential free contact for Fire & Fault. Trickle & Fast Charging Facility.
Add to cart

ASES Six Zone microprocessor based Conventional Fire Alarm Panel, LCD and LED both indication available, inbuilt battery charger Model No. IR-6Z

 8,555.00
Zone Wise fire fault LED indication. Zone Wise isolation facility. Auto Dialer Attachable Facility. Mains On, System On, Charger On, visual indications. External s w for reset, silence, lamp test. External s w to test each zone fire, open, short status manually. 16x2 line LCD Display.
Add to cart

ASES Four Zone microprocessor based Conventional Fire Alarm Panel Model No. IR–4Z .

 5,256.90
Standalone system. With a 16x2 LCD character. 4 zones detection circuit. Fire & Fault potential-free contacts. Common Hooter. And battery Fault Indication. Inbuilt Battery Charger.
Add to cart

ASES Two Zone microprocessor based Conventional Fire Alarm Panel, Model No. IR–2Z

 4,248.00
Standalone system. With a 16x2 LCD character. 2 zones detection circuit. Fire & Fault potential-free contacts. Common Hooter. And battery Fault Indication. Inbuilt Battery Charger.
Add to cart

Ultra Fire Panel 8 – Zone

 15,930.00
Switched Mode Power Supply (95-245)V Modular Construction Auto Resettable Fuse Surge Protection Programmable AC loss delay/Trouble Remainder/Alarm Verification Battery polarity reversible protection Surface Mount Technology Over All current consumption is low. Fully complies with UL -864 and NFPA-72. Rugged CRCA sheet with powder coated finish. Operates on 110 - 220v 50 /60 Hz, AC Mains power supply. 16x2 Dot Matrix LCD Display. 4/8 Class B Style ?B ? or Style ?C? initiating device circuit (IDC).
Add to cart

Ultra Fire Panel 6 – Zone

 14,160.00
2 x 16 character backlit LCD display. (4 x 20 character, optional) 64 / 128 / 256 Events logging facility with real time clock and keypad. (optional) 2 Wire Communication facility via RS 485 Port. (For Repeater Panel) (optional) BMS attachment Lamp test features. Complete with integral power supply and battery charger for SMF battery. NO/NC contacts for both fire and fault. Switches to enable on board operation. LCD and LED Indication for open, short circuit, Isolate, Fire in each zone.
Add to cart

Ultra Fire Panel 4 – Zone

 7,670.00
Conventional 4 Zone Fire Panel And Detection System, 50hz
Add to cart

Ultra Fire Panel 2 – Zone

 7,080.00
Switch Mode Power Supply. Modular Construction, Serviceable. Surface Mount Technology. Battery polarity & deep discharge protection. As per IS -15908: 2011 Standard. 16 X 2 Dot Matrix LCD Display. Standby battery backup with built in charging. Fire / Fault status in unambiguous colored LED indication. Switch Mode Power Supply. Tactile Keypad for easy panel operation. System on indication. Main, Standby status indication. Low Battery visual warning with audible tone. Relay output for actuators for Fire and Fault. Lamp Test facility Zone wise one man walk Test Facility. Zone wise Isolation facility with loop voltage cut off. Compatible to all type of Conventional Detectors. Optional Zone Wise Sounder / Zone Wise Contact.
Add to cart

Ravel RE-9064 Conventional Fire Alarm Panel System 64 Zones

 92,512.00
Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 - 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network. 20 X 4 Dot Matrix LCD display. Alphanumeric keypads. RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications. Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network.
Add to cart

Ravel RE-9048 Conventional Fire Alarm Panel System 48 Zones

 71,862.00
Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 - 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network. 20 X 4 Dot Matrix LCD display. Alphanumeric keypads. RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications. Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network.
Add to cart

Ravel RE-9032 Conventional Fire Alarm Panel System 32 Zones

 42,598.00
Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 - 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network. 20 X 4 Dot Matrix LCD display. Alphanumeric keypads. RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications. Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network via RS-485. Repeater Panel can monitor the status of RE-900 series panels via RS-485 Network communication. User can Disable / Enable the Zone of Fire Alarm Control Panel Connected in network. Ravel Indian Manufacturer, International standard. Operates on RS-485 communication. Repeats all the parameters of the main FACP.
Add to cart

Ravel RE-9024 Conventional Fire Alarm Panel System 24 Zones

 31,978.00
Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 - 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network.
Add to cart